Homepage/ NEWS/ Saphenous Vein Cutdown: A Step-by-Step Drill with LV9-1 Saphenous Vein Cutdown: A Step-by-Step Drill with LV9-1 Saphenous Vein Cutdown: A Step-by-Step Drill with LV9-1 The BIX-LV9-1 is a lower-leg model built for a procedure that sits at the edge of most curricula: great saphenous vein cutdown. It has layered skin and subcutaneous tissue with realistic tension, a 14.4 × 3.9 cm groove above the medial malleolus, and a replaceable vessel module embedded in that groove. For a skill that is rarely performed but occasionally decisive, a benchtop model is a reasonable way to keep it taught. Quick answer: LV9-1 is an artificial leg with a replaceable great saphenous vein module, layered skin and subcutaneous tissue, and a 14.4 × 3.9 cm access groove above the medial malleolus. Reference price US $191.50. It supports cutdown and vessel-repair practice, not arterial access. Why cutdown still gets taught Peripheral venous cutdown is a rescue technique when IV access fails and central access is not available or not appropriate. It is uncommon enough that trainees rarely see it in a clinical placement, and urgent enough that the first attempt cannot be a learning attempt. Lanter's chapter on venous cutdown in Clinical Procedures in Emergency Medicine (2010) and Kile's atlas chapter on peripheral venous cutdown (2022) both treat it as a procedure with a narrow window and a strict sequence. The model does not reproduce the patient. It reproduces the anatomy and the tissue planes, which is the part that can be practised. The procedure, as the model allows it Landmark. Identify the medial malleolus and the course of the great saphenous vein — roughly one fingerbreadth anterior and superior to the malleolus.Incision. A transverse or slightly oblique incision over the vein, long enough to work through.Dissection. Through skin, then subcutaneous tissue, until the vessel is exposed. The layered construction is what makes this step meaningful.Isolation. Pass ties proximal and distal, lift the vessel.Cannulation. Venotomy, insert the catheter, secure it, close the skin.Assessment. Confirm flow, dress the site, document. Step 3 is where the model earns its price. A single-layer pad teaches the incision but not the depth judgement; a layered leg forces the trainee to stop and identify what they are cutting. Specification and what to check FeatureLV9-1 detailWhy it mattersStructureArtificial leg plus great saphenous vein incision moduleOne leg supports repeated vessel changesTissueSkin and subcutaneous tissue, clear layering, realistic tensionTeaches depth controlMaterialImported PVC, mould-castWipe-clean, dimensionally stableAccess groove14.4 cm long, 3.9 cm wide, above the medial malleolusMatches the surgical fieldVessel moduleReplaceable, entire moduleConsumable cost is the module, not the legPriceUS $191.50 referenceLow entry cost for a rarely taught skill Ask three questions before ordering: how many vessel modules come with the leg, what a replacement module costs, and whether the leg can be used for repeated cannulation without re-casting. The answers determine the real cost per learner. Building a 30-minute session MinutesActivityNotes0–5Landmark and mark the siteNo incision until the mark is checked5–10Incision and blunt dissectionName each layer as it is divided10–18Vessel isolation and controlProximal and distal ties18–25Cannulation and closureConfirm the catheter is secure25–30Debrief: what would you do differentlyOne technical, one judgement point Run it once as a demonstration with the model open, then let learners work on a closed leg. Seeing the vessel first removes the exact difficulty the exercise is meant to create. Phlebotomy and the same leg The model is also marketed for phlebotomy training, and Taniguchi's 2008 study in BMC Medical Education describes a simulation programme for phlebotomy that improved trainee performance. If your programme teaches both venepuncture and cutdown, the same leg can serve both stations — but keep the cutdown module separate from the venepuncture site, because repeated needle punctures will degrade the skin before the vessel module needs replacing. Limits No arterial pressure, no bleeding simulation, no ultrasound-compatible tissue, and no patient movement. It is not a substitute for supervised clinical experience; it is a way to make the first supervised attempt less tentative. The model also does not reproduce the saphenous nerve, which is the structure most likely to be injured — teach that relationship on a diagram beside the leg. Procurement Reference price US $191.50. Request the module pack price and the case dimensions; the model ships in a fitted case with instruments, which makes it practical for outreach teaching. For a quote covering six legs and a year of vessel modules, write to chinoncpr@adaanatomy.com with your annual learner count. FAQ Q1. Is the vessel module replaceable? Yes. The entire vessel module can be replaced, and the leg is designed around that. Q2. Can it be used for arterial cutdown? No. It is configured for the great saphenous vein. Q3. Does it include instruments? The product image shows a fitted case with instruments; confirm the packing list, since instrument grade varies by order. Q4. How large is the access groove? 14.4 cm long and 3.9 cm wide, positioned above the medial malleolus. Q5. Is it suitable for ultrasound-guided practice? Not stated, and the PVC tissue is unlikely to be ultrasound-compatible. Do not assume it. Q6. What is the price? US $191.50 reference per unit, quantity-dependent, freight additional. Ordering notes Reference price: US $191.50. Product page: BIX-LV9-1 phlebotomy model. Catalogue: clinical models. More procedure guides: news. Module packs and case contents: chinoncpr@adaanatomy.com. References Lanter P. (2010). Venous Cutdown. Clinical Procedures in Emergency Medicine. https://doi.org/10.1016/b978-1-4160-3623-4.00023-7Kile D. (2022). Peripheral Venous Cutdown. Atlas of Emergency Medicine Procedures. https://doi.org/10.1007/978-3-030-85047-0_5Taniguchi R. et al. (2008). A simulation program for phlebotomy. BMC Medical Education. https://doi.org/10.1186/1472-6920-8-7 Previous: Wrist vs Shoulder Arthroscopy Models: LV49 and LV50 Next: null NEWS Products Medical Series Skeleton Series Torso Series Anatomical Series Acupuncture Series Biology Series Have Question? Call Us:+86 19937901373 If you have question and problems,click the button on the right to submit your request Get started Have Question? Call Us+86 19937901373 If you have question and problems,click the button on the right to submit your request Get started