Homepage/ NEWS/ Wrist vs Shoulder Arthroscopy Models: LV49 and LV50

Wrist vs Shoulder Arthroscopy Models: LV49 and LV50

Wrist vs Shoulder Arthroscopy Models: LV49 and LV50

Two benchtop arthroscopy models, one decision. The BIX-LV49 is an adult right wrist with replaceable ligaments and three TFCC injury variants; the BIX-LV50 is an adult right shoulder with a closed capsule and two operative targets. They cost within US $30 of each other, so the choice is about curriculum, not budget.

Quick answer: LV49 (US $559.74) trains wrist arthroscopy through dorsal radial and dorsal ulnar portals with radial, central and global TFCC lesions. LV50 (US $589.20) trains shoulder arthroscopy of the joint and biceps with a complete ligament-closed capsule. Buy wrist first if your service sees more TFCC pathology; buy shoulder first if rotator cuff and biceps work dominates.

Side-by-side

CriterionBIX-LV49 wristBIX-LV50 shoulder
AnatomyAdult right palm: skin, muscles, radius, ulna, carpal bones, carpal disc, intra-articular ligamentsAdult right shoulder: skin, rotator muscles, tendons, ligament-closed capsule
Portals / approachesDorsal radial and dorsal ulnarArthroscopic access to shoulder joint and biceps
Pathology variantsRadial laceration, central damage, global (TFCC) damageNot itemised; anatomy-based practice
Replaceable partsLigaments replaceable; model disassemblesModel detachable; no replaceable pathology listed
Teaching dual useYes — wrist function model when closedYes — shoulder function model when closed
Reference priceUS $559.74US $589.20

What the wrist model does that the shoulder cannot

The LV49 ships with three grades of triangular fibrocartilage complex injury: a radial laceration, a central tear, and a global tear. That is a curriculum in a box. A trainee can practise the same portal with three different lesions and learn that the same view does not mean the same repair. The replaceable ligament design also means the model degrades gracefully: when a ligament is cut through, you replace the ligament, not the hand.

Slutsky's chapter on wrist arthroscopy portals (2007) and Krustins's 2022 review of wrist arthroscopy both describe portal anatomy as the rate-limiting skill for novices. A model that lets a trainee place a portal 20 times in an afternoon addresses exactly that limit. Mak's chapter on degenerative wrist conditions (2016) is useful for deciding which pathology variants to teach first.

What the shoulder model does that the wrist cannot

The LV50 presents a closed capsule with rotator muscles and tendons, and two operative targets: the glenohumeral joint and the biceps. That geometry is what makes shoulder arthroscopy hard — the humeral head blocks the view, and the biceps groove is a landmark that has to be found by feel and image, not by direct sight.

Henn's cadaver-model study in Arthroscopy (2013) found that simulator training improved shoulder arthroscopy performance, and Tofte's validation of a virtual arthroscopy simulator (2016) supports the same principle: repeated, deliberate practice transfers. A benchtop model is not a virtual simulator, but it delivers the same repetition at a fraction of the capital cost, with real instruments.

The decision in three questions

  1. Which procedure will your learners perform first in theatre? Buy the model that matches the first procedure, not the most interesting one.
  2. Do you need pathology variants or normal anatomy? LV49 gives you three lesions; LV50 gives you one normal capsule.
  3. What is the consumable plan? LV49 needs replacement ligaments; LV50 needs a plan for capsule wear at the portal sites. Ask both suppliers for the replacement price before ordering.

Using both in one course

If budget allows both, run them as a two-station rotation: wrist in the morning, shoulder in the afternoon, with a shared debrief on portal planning and scope orientation. The skills overlap more than the anatomy suggests — both reward triangulation and both punish a rushed entry.

Procurement notes

Prices are US $559.74 and US $589.20 reference, quantity-dependent. Neither page lists a consumable pack, so request the replacement ligament set (LV49) and the portal repair policy (LV50) with the quotation. Both models are marketed as dual-purpose anatomy teaching aids when closed, which helps justify the spend to a curriculum committee.

For a combined quotation, write to chinoncpr@adaanatomy.com with the number of stations and the procedures you teach.

FAQ

Q1. Are these virtual simulators? No. Both are physical benchtop models used with real arthroscopic instruments.

Q2. Which one includes TFCC injuries? LV49, with radial laceration, central and global damage variants.

Q3. Can the shoulder model simulate rotator cuff tears? The page does not list tear variants; it lists a closed capsule with the joint and biceps as operative targets.

Q4. Are replacement ligaments available for LV49? Yes, the model is designed with replaceable ligaments, though the page does not list a part number.

Q5. Can they be used to teach anatomy without a scope? Yes. Both can be used as function models when closed.

Q6. What is the price difference? US $29.46 at reference prices: US $559.74 for LV49 versus US $589.20 for LV50.

Ordering notes

Reference prices: US $559.74 (LV49) and US $589.20 (LV50). Product pages: BIX-LV49 wrist arthroscopy model and BIX-LV50 shoulder arthroscopy model. Catalogue: clinical models. More comparisons: news.

Replacement parts and combined quotes: chinoncpr@adaanatomy.com.

References

  1. Slutsky D. (2007). Wrist Arthroscopy Portals. Techniques in Wrist and Hand Arthroscopy. https://doi.org/10.1016/b978-0-443-06697-9.50006-0
  2. Henn R. et al. (2013). Shoulder arthroscopy simulator training improves performance in a cadaveric model. Arthroscopy. https://doi.org/10.1016/j.arthro.2013.02.013
  3. Tofte J. et al. (2016). Validation of a virtual arthroscopy simulator. Arthroscopy. https://doi.org/10.1016/j.arthro.2016.09.014

Have Question? Call Us:+86 19937901373

If you have question and problems,click the button on the right to submit your request

Have Question?

Call Us+86 19937901373

If you have question and problems,click the button on the right to submit your request