Homepage/ NEWS/ A2132 Pupil Model: How Light Reflex Is Taught

A2132 Pupil Model: How Light Reflex Is Taught

The BIX-A2132 is a photoelectric pupil regulation model, 50 × 60 × 12 cm, that changes the modelled pupil under light stimulation so that a class can watch constriction instead of being told about it. The reference price is US $556.92.

Quick answer. Buy the A2132 if you teach the pupillary light reflex and need every student to see the same change at the same moment. Do not buy it if you need a full eye for fundoscopy, slit-lamp practice or tonometry — the A2132 demonstrates the reflex, not the examination.

At a glance

ItemDetail on the product pageTeaching consequence
ModelBIX-A2132 pupil regulation modelOne demonstration unit per classroom
Size50 × 60 × 12 cmWall or easel format, readable from the back row
ControlPhotoelectric, adjusts pupil changeLight stimulus drives the response
DemonstrationPupil constriction under lightThe reflex is shown, not described
Reference priceUS $556.92One unit per teaching room, not per student
CertificationISO and CE per the page summaryUsable in tender documentation

Why the reflex is hard to teach without a model

The pupillary light reflex is a five-step pathway: retina, optic nerve, chiasm, pretectal nucleus, Edinger-Westphal nucleus, oculomotor nerve, ciliary ganglion, sphincter pupillae. Students can recite it and still fail to reason about it, because the pathway is invisible and the response is fast.

A model that constricts on demand slows the event down. The tutor can apply the stimulus, hold the change, and ask where a lesion would have to sit for the reflex to be absent on one side with a normal direct response on the other. That question is the difference between memorising a diagram and understanding a bedside finding.

A 20-minute reflex tutorial

  1. Minutes 0–4 — baseline. Students describe the resting pupil and name the two muscles that set its size.
  2. Minutes 4–9 — direct reflex. Tutor applies light; students narrate the pathway while watching the pupil constrict.
  3. Minutes 9–14 — consensual reflex. Tutor asks what the other eye should do and why, then shows the model's response.
  4. Minutes 14–18 — lesion logic. Tutor poses three lesions — optic nerve, oculomotor nerve, brainstem — and students predict the reflex pattern for each.
  5. Minutes 18–20 — check. Three predictions, no notes.

What the A2132 cannot do

  • No fundus. The posterior segment is not represented, so retinal causes cannot be inspected.
  • No eye movement. Extraocular muscles and gaze are outside the model.
  • No measurement. Pupil diameter in millimetres is not reported; the change is qualitative.
  • No pathology set. A fixed, dilated pupil and an afferent defect are reasoned about, not shown.
  • No slit-lamp or tonometry. It is a demonstration model, not an examination trainer.

Where it fits in a curriculum

The A2132 belongs in the lecture room and the simulation briefing room, not the skills lab. Its job is to make a reflex visible before students meet a patient whose reflex is abnormal, and to give an instructor a shared object for the lesion-reasoning questions that follow.

For programmes that also teach the neurological examination, the model pairs well with a head model that shows the cranial nerves, because the two together cover the pathway and the anatomy without duplicating either.

Email chinoncpr@adaanatomy.com with the classroom voltage and whether you need a wall mount or an easel, and ask for the power specification before the order is confirmed.

Specifications and ordering facts

FieldValue
Product numberBIX-A2132
CategoryEye models, anatomical series
Dimensions50 × 60 × 12 cm
ControlPhotoelectric, pupil change under light stimulation
Reference priceUS $556.92 before freight
CertificationISO and CE, per the product page

FAQ

Q1. How does the pupil change? The page describes photoelectric control that adjusts the pupil change, so the response is driven by light stimulation rather than by a manual lever.

Q2. What size is the model? 50 × 60 × 12 cm.

Q3. Can students measure pupil diameter? No. The model demonstrates constriction; it does not report a millimetre value.

Q4. What is the reference price? US $556.92 before freight. Ask for the power requirement and the mounting option at the same time.

Q5. Is it a full eye for examination practice? No. It is a pupil demonstration model; fundoscopy and tonometry require different trainers.

Q6. How is it powered? The page does not state the supply. Confirm voltage and whether a plug adapter is included before ordering for a non-Chinese classroom.

References

  1. Araki S, et al. 2026. Macroscopic pupillary examination for detecting autonomic dysfunction of the eye. Journal of Visualized Experiments. https://doi.org/10.3791/72489
  2. Shi Q, et al. 2026. Ultrasonographic pupil assessment in patients with severe traumatic brain injury. American Journal of Critical Care. https://doi.org/10.4037/ajcc2026776
  3. Cha YS, et al. 2023. Quantitative pupillary light reflex assessment for prognosis of carbon monoxide poisoning. Frontiers in Medicine. https://doi.org/10.3389/fmed.2023.1105705

Contact. For a unit quotation, the power specification or the mounting option, email chinoncpr@adaanatomy.com. Product page: https://www.chinoncpr.com/eye-model/pupil-regulation-model-A2132 · Eye models: https://www.chinoncpr.com/eye-model · All articles: https://www.chinoncpr.com/neslist.html

Have Question? Call Us:+86 19937901373

If you have question and problems,click the button on the right to submit your request

Have Question?

Call Us+86 19937901373

If you have question and problems,click the button on the right to submit your request