Homepage/ NEWS/ BIX-LV7: 20 mm or 30 mm Bowel for Anastomosis Practice?

BIX-LV7: 20 mm or 30 mm Bowel for Anastomosis Practice?

BIX-LV7: 20 mm or 30 mm Bowel for Anastomosis Practice?

The BIX-LV7 is an intestinal anastomosis training model supplied in two diameters, 20 mm and 30 mm, with a double layer that reproduces serosa and mucosa so that hand-sewn and stapled techniques can be rehearsed. It is a consumable practice segment, not a full laparotomy simulator.

Quick answer. Choose 30 mm for first-year practice and stapled anastomosis, where the lumen is easy to see and the suture line is forgiving. Choose 20 mm for advanced hand-sewn practice, where a single misplaced bite narrows the lumen. The model gives realistic tissue layers but no bleeding, no mesentery and no tension.

At a glance

ItemSpecificationTeaching consequence
Diameters20 mm and 30 mmTwo difficulty levels from one product line
LayersSerosa and mucosa simulatedFull-thickness and seromuscular bites can be taught
TechniquesAll common anastomosis methodsHand-sewn, single or double layer, and stapled
MaterialSoft synthetic bowel segmentNeedle passes with realistic resistance
CertificationISO 9001 / 14001 / 45001, CEUsable in tendered training packages
PriceQuote per orderOrder both sizes to compare

Why diameter is the whole decision

Anastomosis is a sizing problem before it is a suturing problem. At 30 mm, the lumen accepts a standard stapler and the student can see the mucosa while placing the first stitch. At 20 mm, the same stitch consumes a much larger share of the circumference, so each bite must be smaller and more evenly spaced.

That is why the two sizes are not interchangeable. Teaching a novice on 20 mm produces hesitation and a tendency to take large bites; teaching an experienced trainee only on 30 mm hides the narrowing that causes a stricture.

A progression that uses both sizes

  1. 30 mm, interrupted single layer. Twelve to fourteen bites, even spacing, knots on the serosal surface.
  2. 30 mm, continuous single layer. Same lumen, continuous closure; the student learns to maintain tension.
  3. 20 mm, interrupted. Half the bite size, double the precision requirement.
  4. 20 mm, stapled. Confirm the stapler size against the lumen before firing.
  5. Leak check. Distend with air or water; a leaking anastomosis is visible immediately on a synthetic segment.

What the model teaches that a video cannot

The model gives resistance. A needle that is too large tears the serosa; a bite that is too shallow pulls out under tension; a knot that is too tight strangulates the edge. None of those errors can be felt on a screen, and all of them show up as a leak at the end of the exercise.[1][3]

What the model cannot do

  • No bleeding. There is no vessel to coagulate and no haematoma to recognise.
  • No mesentery. Mesenteric orientation and vascular supply are not represented.
  • No tension or diameter mismatch. A real anastomosis may join two different calibres; the model is uniform.
  • No healing. There is no inflammatory phase, no collagen remodelling and no leak on day five.
  • No scoring. Assessment is by direct inspection and leak test.

Buying notes

  • Order both diameters: the progression is the product's main teaching value.
  • Ask how many segments are in a pack; the model is a consumable and the per-student cost depends on pack size.
  • Confirm the segment accepts the suture and stapler sizes used in your department.
  • Store flat and away from heat; a creased segment is harder to suture evenly.
  • Email chinoncpr@adaanatomy.com for the pack configuration and a course-set quotation.

FAQ

Q1. What sizes does the LV7 come in? Two diameters: 20 mm and 30 mm.

Q2. Which anastomosis techniques can be practised? Hand-sewn single and double layer, plus stapled techniques, on a segment with simulated serosa and mucosa.

Q3. Is it reusable? It is a practice segment; once sutured and cut it is consumed. Confirm pack size when ordering.

Q4. Does it bleed? No. There is no vascular simulation.

Q5. Is it certified? The product page lists ISO 9001, ISO 14001, ISO 45001 and CE certification.

Q6. What is the price? Price is quoted per order and depends on diameter and pack size.

References

  1. Kokelaar RF, et al. 2013. Hand-sewn anastomosis incurs higher risk of leak following reversal of ileostomy. International Journal of Surgery. https://doi.org/10.1016/j.ijsu.2013.06.198
  2. Faris A, et al. 2019. Stapled versus hand-sewn method for small bowel anastomosis surgery. Al-Qadisiyah Medical Journal. https://doi.org/10.28922/qmj.2019.15.1.126-130
  3. Mehrdadi B, et al. 2018. Introduction and assessment of an inanimate model for basic surgical skills training. Journal of Surgical Simulation. https://doi.org/10.1102/2051-7726.2018.0006

Contact. For pack configuration, both diameters or a course-set quotation, email chinoncpr@adaanatomy.com. Product page: https://www.chinoncpr.com/clinical-models/intestinal-canal-anastomosis-model-LV7 · Clinical models: https://www.chinoncpr.com/clinical-models · All articles: https://www.chinoncpr.com/neslist.html

Have Question? Call Us:+86 19937901373

If you have question and problems,click the button on the right to submit your request

Have Question?

Call Us+86 19937901373

If you have question and problems,click the button on the right to submit your request