Neonatal PICC Training: Reading Depth on BIX-L67B

Neonatal PICC Training: Reading Depth on BIX-L67B

Neonatal PICC Training on BIX-L67B: Landmarks, Length, and the Transparent-Chest Rule

Short answer: BIX-L67B is a newborn manikin built for peripheral and central venous cannulation, including insertion of a central venous catheter through a peripheral vein. Its published features are anatomical and visual: a transparent chest wall showing bilateral venous channels, landmarks for the basilic, cephalic, jugular and subclavian veins and the superior vena cava, direct sight of ribs and heart for measuring insertion length, and a rule that makes assessment objective — the catheter is visible in the transparent superior vena cava when it is correctly placed, and invisible when it is not.

Key takeaways

  • The visibility rule is the assessment. No electronics, no scoring software: either the tip shows in the SVC window or the attempt failed.
  • Length measurement is taught, not assumed. Seeing ribs and heart lets a trainee verify the external measurement against internal anatomy.
  • Transparent chest is a teaching device, not a clinical simulation. In a real neonate you confirm position by imaging, so pair the model with the imaging step.
  • Soft, cleanable skin matters more than realism here, because PICC practice is repetitive and hygiene between attempts is mandatory.
  • PICC competence depends on structured training and maintenance practice, and simulation shortens the learning curve [1][2][3].

The model at a glance

ItemPublished detail
ModelBIX-L67B
Product name on pageNewborn Peripheral & Central Vein Cannula Manikin
CategoryClinical Medicine Models
Design basisNeonatal physiological and anatomical proportions
MaterialImported plastic, soft elastic skin, easy to clean
ProcedureCentral venous catheter placement via peripheral vein (PICC)
Chest wallTransparent, showing bilateral venous channels
LandmarksBasilic, cephalic, jugular, subclavian vein, superior vena cava
Position checkCatheter visible in the transparent SVC when correct; invisible when not
Price / carton / weightNot published

Step sequence the manikin can actually assess

StepTrainee actionHow BIX-L67B shows success or failure
1. Site selectionChoose a peripheral vein on the arm, avoiding flexion areas.Bilateral channels are visible through the chest wall, so the tutor can see the chosen route.
2. MeasureMeasure from insertion site to the sternal notch or shoulder, per protocol.Ribs and heart are visible for checking the external measurement against internal landmarks.
3. PrepareClean the skin, flush the catheter, assemble the field.Skin is smooth and cleanable, so aseptic routine can be scored.
4. InsertAdvance the catheter through the peripheral vein toward the SVC.Route is traceable through the transparent wall.
5. ConfirmLook for the catheter tip in the SVC window.Visible = correct; invisible = the tip is not in the SVC, so reposition.
6. SecureFix the catheter, record length, document.Insertion length can be compared with the measured value.

Why an objective visibility rule changes teaching

Neonatal PICC insertion is a low-volume, high-consequence skill: individual clinicians may place few catheters, and complications are serious. A survey of PICC training and maintenance practice found substantial variation in how clinicians are trained and how competence is maintained [1]. A randomised trial of a PICC virtual simulator in neonatal nursing found that structured simulation improved learning outcomes compared with conventional teaching [2]. Guidance on neonatal central venous access emphasises tip position and insertion depth as the controllable variables — which is exactly what a transparent-chest model lets a trainee practise [3].

The design detail that matters most is the negative case. Many trainers only show success; this one makes a malpositioned catheter disappear, so the trainee has to recognise failure and correct it. That is the behaviour that transfers to a real NICU, where the corrective step is to withdraw and reassess rather than to push further.

What to verify before ordering

QuestionWhy it matters
Which catheter gauges fit the venous channels?Neonatal PICC sizes are small; a channel that only accepts larger catheters teaches the wrong feel.
Is the venous channel replaceable?The channel and skin puncture sites are the wear parts.
Does it include an umbilical route?Umbilical lines are a separate neonatal skill; the page covers peripheral and central venous routes only.
Is a cleaning protocol supplied?Repeated practice needs a validated cleaning routine between trainees.
Carton quantity, size and gross weightNot published; needed for freight.
Lead time and warrantyTender requirement.

Email chinoncpr@adaanatomy.com with those questions and your annual NICU cohort. If you also train umbilical catheterisation, ask what model covers it — this one does not.

FAQ

Q1. What is BIX-L67B?
A newborn manikin for peripheral and central venous cannulation, including PICC insertion, with a transparent chest wall showing the venous route.

Q2. How do I know the catheter is in the right place?
The catheter is visible inside the transparent superior vena cava when correctly positioned; if it is not visible, the tip is not in the SVC.

Q3. Can insertion length be practised?
Yes. The page states ribs and heart are directly observable so the correct inserted length can be measured.

Q4. Which veins are represented?
Basilic, cephalic, jugular and subclavian veins, with the superior vena cava.

Q5. Is a price published?
No. BIX-L67B is a quotation item with no carton data on the page.

Q6. How do I request a quotation?
Email chinoncpr@adaanatomy.com with model BIX-L67B, quantity, catheter sizes used in your unit and your delivery city.

Request a quotation

Write to chinoncpr@adaanatomy.com for the BIX-L67B specification sheet, the replacement venous-channel price and a landed-cost quotation. Ask for the cleaning protocol at the same time — it is the document your infection-control team will ask for.

→ Product page: BIX-L67B Newborn Peripheral & Central Vein Cannula Manikin — full specification, packing data and a quotation request form.

References

  1. Current training in percutaneously inserted central catheter (PICC) placement and maintenance. J Perinatol. 2020.
  2. Development and evaluation of a PICC virtual simulator in neonatal nursing: a randomized controlled trial. Nurse Educ Today. 2024.
  3. Ultrasound-guided central venous access in the NICU: indications, insertion and management. Eur J Pediatr. 2026.

Have Question? Call Us:+86 19937901373

If you have question and problems,click the button on the right to submit your request

Have Question?

Call Us+86 19937901373

If you have question and problems,click the button on the right to submit your request