Homepage/ NEWS/ MY800AX Hysteroscopy Simulator: RFQ Checklist MY800AX Hysteroscopy Simulator: RFQ Checklist MY800AX Hysteroscopy Simulator: What to Put in the RFQ Short answer: BIX-MY800AX is a hysteroscopic surgery simulation training system built around an adult female lower torso with a simulated vagina, cervix and uterine cavity, plus a dedicated endoscope. The page lists fallopian tube intubation, fluid operation, IUD removal, embryonic tissue residue removal and polyp resection under monitor guidance. It is a procedure trainer, not a full operating-room tower — so the RFQ must define what is included beyond the torso and endoscope. Key takeaways The anatomy is the product: female lower torso with vagina, cervix and uterine cavity. A dedicated endoscope is included according to the page; the monitor and instrument set are not described. Five procedures are named: tubal intubation, tubal fluid operation, IUD removal, tissue-residue removal and polyp resection. Training is monitor-guided, so the visual chain — endoscope, camera, light source, monitor — must be specified as one system. Price, carton data and module list are not published; all three belong in the RFQ. What the page documents ItemPublished detail ModelBIX-MY800AX CategoryClinical Medicine Models AnatomyAdult female lower torso: simulated vagina, cervix, uterus EndoscopeDedicated endoscope included (per page) ProceduresFallopian tube intubation; tubal fluid operation; IUD removal; embryonic tissue residue removal; polyp resection GuidanceMonitor image Intended usersHospitals and schools CertificationISO 9001 / 14001 / 45001 and CE stated Price / cartonNot published The system boundary: what “simulator” can mean A hysteroscopy trainer is only as useful as the visual chain that feeds the monitor. The page names the torso and a dedicated endoscope; it does not name the camera, light source, monitor, insufflation, instrument set or recording system. Those may be included, optional or buyer-supplied. If the RFQ does not state the boundary, two quotes that look similar can differ by an entire tower. ComponentStatus on the pageRFQ instruction Female lower torso with uterine cavityIncludedState the number of replaceable cavities or modules. Dedicated hysteroscopeIncluded (per page)Specify diameter, angle and whether a spare is included. Camera and light sourceNot describedAsk whether included; specify resolution and compatibility. MonitorNot describedAsk for size, input type and mounting. InstrumentsNot describedList the instruments needed for the five procedures. Consumable modulesNot describedAsk for part numbers, unit price and expected life. Installation and trainingNot describedAsk for on-site commissioning and a train-the-trainer day. Five procedures, five acceptance tests Tubal intubation. Pass the catheter under monitor guidance and confirm visualisation of the ostium. Tubal fluid operation. Confirm flow and return without leakage at the cervical seal. IUD removal. Place and retrieve a simulated device without damaging the cavity module. Tissue-residue removal. Confirm the residue is visible and removable with the supplied instruments. Polyp resection. Confirm the polyp model can be resected and that the module can be replaced. Run these five tests at commissioning, not after the invoice is paid. Each test should name the instrument, the visual endpoint and the person who signs it off. What the evidence says about hysteroscopy simulation A prospective study examined retention of hysteroscopic skills after simulation training in gynecology and obstetrics residents [1]. A systematic review compared objective technical skill performance in simulation-based gynecologic endoscopy training [2]. A second systematic review focused on how hysteroscopy competencies are trained and assessed [3]. The consistent message is that simulation works when it is scheduled, assessed and repeated — not when it is purchased and stored. The limitation is the same for every simulator: a model cannot reproduce every anatomical variant, complication or team interaction. MY800AX is a procedure trainer for the uterine cavity and the five named tasks. It does not replace operating-room supervision. RFQ template SectionWhat to write ScopeNumber of systems, intended users, annual trainee throughput. AnatomyNumber of uterine cavity modules; replacement cycle; whether variants are available. ImagingEndoscope, camera, light source, monitor; resolution and spares. InstrumentsInstrument list mapped to the five procedures. ConsumablesPart numbers, unit prices, minimum order and lead time. ServiceWarranty, response time, spare parts holding, on-site training. CommercialIncoterm, lead time, payment terms, validity of quote. Send the template to chinoncpr@adaanatomy.com with your trainee throughput and the procedures you need to teach. We will return a line-item quote that separates the torso, the imaging chain, the instruments and the consumables, so nothing is hidden in a single lump sum. FAQ Q1. What is BIX-MY800AX? A hysteroscopic surgery simulation training system based on an adult female lower torso with a simulated vagina, cervix and uterine cavity, plus a dedicated endoscope. Q2. Which procedures can be practised? Fallopian tube intubation, tubal fluid operation, IUD removal, embryonic tissue residue removal and polyp resection under monitor guidance. Q3. Is a monitor included? The page does not state that a monitor, camera or light source is included. Specify these in the RFQ. Q4. Is the uterine cavity replaceable? The page does not state a replacement module or part number. Ask for the consumable list and expected life. Q5. Who is it intended for? The page names hospitals and schools as the training settings. Q6. How do I get a price? Price is not published. Email chinoncpr@adaanatomy.com with the RFQ template above and your annual trainee number. Request a line-item quotation Write to chinoncpr@adaanatomy.com for a line-item quotation on BIX-MY800AX. Ask for the imaging chain, instrument list and consumable prices to be quoted separately, and request a commissioning checklist with the five acceptance tests so the system is verified before sign-off. References Retention of hysteroscopic skills after simulation training: a prospective study in gynecology and obstetrics residents. European Journal of Obstetrics, Gynecology, and Reproductive Biology. 2026. Effectiveness of Simulation-Based Gynecologic Endoscopy Training: A Systematic Review Comparing Objective Technical Skill Performance. International Journal of Women's Health. 2026. Training and assessment of competencies in hysteroscopy - A systematic review. European Journal of Obstetrics, Gynecology, and Reproductive Biology. 2026. Previous: BIX-L68B Central Vein Puncture Model: Training Guide Next: null NEWS Products Medical Series Skeleton Series Torso Series Anatomical Series Acupuncture Series Biology Series Have Question? Call Us:+86 19937901373 If you have question and problems,click the button on the right to submit your request Get started Have Question? Call Us+86 19937901373 If you have question and problems,click the button on the right to submit your request Get started